HomeProductsPatient MonitorP Monitor CMS9000 & Pr/Ni...

P Monitor CMS9000 & Pr/Nibp/Spo2/Tem/ECG

R26,789.10 Inc. Vat

Add to wishlist
Share

    P Monitor CMS9000 & Pr/Nibp/Spo2/Tem/ECG

     

    P Monitor CMS9000 & Pr/Nibp/Spo2/Tem/ECG

    Features:

    • 12.1″ Screen, Colour TFT SCreen, waveform up to 8 channels.
    • Light and portable with a built-in rechargeable battery.
    • Up to 10 kinds of monitor parameters.
    • Arrhythmia analysis, pace marker detection, and S-T Segmentanalysis.
    • 72 Hour storage and review of trend grams and tables, 40-second review of olographic waveforms.
    • Built-in recorder – optional.
    • All-round monitor of an adult, pediatric, and neonatal.
    • Electrosurgical unit and defibrillation protected.

     

    Specifications:

    Display: Colour TFT Screen.

     

    NIBP

    • Method: Oscillometry.
    • Operation Modes: Manual/Automatic/STAT
    • Measurement unit: mmGh/kPa selectable
    • Measurement types: Systolic, Diastolic, Mean
    • Measurement range: Adult 10-270mmHG
    • Overpressure protection: Yes
    • Resolution: 1mmHg
    • Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
    • Alarm: Systolic, Diastolic, Mean

     

    SP02

    • Measurement range: 0-100%
    • Accuracy:±2 digit (70~100%) 0~69% unspecified
    • Alarm range: 0-100%

     

    ECG: 5-lead or 3-lead selectable

    • Input: 5 lead: RA, LA, RL, LL, V or R, L, N, F, C
    • Lead selection: I, II, III avr, avl, avf, vx, CAL
    • Gain selection: 12.5mm/s, 25mm/s, 50mm/s
    • Accuracy:±1bpm or±1%, whichever is greater.
    • Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation.
    • Calibration Signal: 1mV±5%
    • Operation modes: Dianostic, Monitor, Surgery
    • Alarm range: 15-300bpm
    • Peadiatric/Neonatal: 15-350bpm
    • Alarm range: -2.0mV~2.0mV
    • S-T detection: Yes, Arrhythmia analysis: Yes
    • Alarm: Yes, audible and visual alarm, alarm events recallable.

     

    Respiration

    • Method: RA-LL impedance
    • Peadiatric/Neonatal: 6-150rpm
    • Alarm range: 6-120rpm
    • Peadiatric/Neonatal: 6-150rpm
    • Apnea Alarm: Yes

     

    Temperature

    • Resolution: 0.1°C
    • Channel: Dual-channel
    • Alarm range: 0°-50°C

     

    Option:

    ETC02

    • Measurement Mode: Side-stream or mainstream
    • Measurement range: EtC02: 0-99mmHg
    • Accuracy: CO2 concentration
    • Apnea Alarm: Yes

     

    CO

    • Method: Thermo-dilution
    • Measurement range: CO0.1-20Lit/min

     

    IBP

    • Channel: 2 channels
    • Pressure transducer: Sensitivity: 5(mV/V/mmHg)
    • Transducer sites: ART, PA, CVP, RAP, LAP, ICP
    • Alarm range: -10~ 300mmHG

    P Monitor CMS9000 cape town.

    Reviews

    There are no reviews yet.

    Be the first to review “P Monitor CMS9000 & Pr/Nibp/Spo2/Tem/ECG”

    Your email address will not be published. Required fields are marked *

    Are you human? Please solve:Captcha